{"product_id":"nuke-performance-cfc-unit-for-brushless-fuel-pumps-competition-fuel-cell-unit-with-integrated-fuel-surge-tank","title":"Nuke Performance CFC Unit for brushless fuel pumps - Competition Fuel Cell Unit, with integrated fuel surge tank","description":"\u003cp\u003e\u003cstrong\u003eThe Nuke Performance CFC Unit, specially developed for use with brushless fuel pumps, such as Protec Cobra Compact and Deatschwerks DW440 Brushless. With integrated fuel surge tank and fuel pump hanger.\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eThe Nuke Performance CFC Unit, specially developed for use with brushless fuel pumps, such as Protec Cobra Compact and Deatschwerks DW440 Brushless. With integrated fuel surge tank and fuel pump hanger.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003ci class=\"iconset iconset-check-box\"\u003e\u003c\/i\u003e Fits your standard \u003cstrong\u003eaftermarket Fuel Cell\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e\u003ci class=\"iconset iconset-check-box\"\u003e\u003c\/i\u003e For \u003cstrong\u003ebrushless fuel pumps\u003c\/strong\u003e with additional venturi pickup\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e\u003ci class=\"iconset iconset-check-box\"\u003e\u003c\/i\u003e Low weight \"\u003cstrong\u003edrop-in surge tank\u003c\/strong\u003e\" for your fuel cell\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e\u003ci class=\"iconset iconset-check-box\"\u003e\u003c\/i\u003e Integrated \u003cstrong\u003e2.0 liter Fuel Surge Tank\u003c\/strong\u003e functionality\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003e\u003ci class=\"iconset iconset-check-box\"\u003e\u003c\/i\u003e Single AN-10 ORB outlet\u003c\/strong\u003e, for a trouble-free installation\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e\u003ci class=\"iconset iconset-check-box\"\u003e\u003c\/i\u003e 100% proof \u003cstrong\u003efor all types of fuel\u003c\/strong\u003e, including ethanol\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe Nuke Performance CFC Unit eliminates the need for an external surge tank which is also needed when running a fuel cell, making it is a perfect solution for fuel-injected systems. Used with PWM control in combination with the CFC Unit prevents emerging heat when running numerous fuel pumps. This is the best way to eliminate the fuel starvation that may otherwise occur in motorsports. And with the new design that accommodates brushless fuel pump installation, it´s also possible to mount venturi pickup points that ensure a full surge tank even at extremely low fuel levels.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ci class=\"iconset iconset-info-circle\"\u003e\u003c\/i\u003e Integrated 2.0 liter surge tank with a billet fuel pump hanger for 1-2 brushless fuel pumps\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eThe unique CFC Unit from Nuke Performance works as a fill plate replacement for fuel cells with the standardized 6x10\" 24-bolt pattern fill plates from manufacturers such as ATL, Premier, Pyrotect, Fuel Safe, Radium, etc. The CFC unit for brushless fuel pumps is the perfect solution for a simplified and efficient high-performing fuel system where safety is of utmost importance. With the integrated drop-in surge tank, this setup eliminates the need for a space-consuming external surge tank.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003ci class=\"iconset iconset-check-box\"\u003e\u003c\/i\u003e The most lightweight solution for your motorsports fuel system\u003cbr\u003e\u003ci class=\"iconset iconset-check-box\"\u003e\u003c\/i\u003e Fits most common FIA-homologated fuel cells\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eWith all the needed fuel pumps mounted within the fuel cell itself, this product is the only thing you need. The simplicity of its design frees up space and weight while increasing safety, as fewer fuel line fittings are necessary and no external fuel pumps are used. With its unique low-profile billet design, this is the most lightweight solution on the market and lets you save crucial weight in your racecar.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cimg src=\"https:\/\/www.nukeperformance.com\/images\/150-05-204_textimage01.jpg\" alt=\"\" width=\"600\" height=\"400\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ci class=\"iconset iconset-info-circle\"\u003e\u003c\/i\u003e Accommodates single or dual internal high-pressure brushless fuel pumps, fewer amps, less heat, and colder fuel\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eThe Nuke Performance CFC Unit for brushless fuel pumps - Competition Fuel Cell Unit, with integrated fuel surge tank is designed to utilize one or two brushless fuel pumps within the integrated surge tank. This lets you choose a smaller pickup fuel pump with fewer amps, less heat, and lower fuel temperature as a result.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003ci class=\"iconset iconset-check-box\"\u003e\u003c\/i\u003e Less heat, fewer amps, lower fuel temperature\u003cbr\u003e\u003ci class=\"iconset iconset-check-box\"\u003e\u003c\/i\u003e Control your fuel flow and pressure with PWM\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe combination of the 6-pin connector lets you use a single or dual brushless fuel pump set up together with the three electrical connectors for the lift pump. This arrangement accommodates either a single or dual fuel pump or a single brushless fuel pump as the pickup pump. The CFC Unit for brushless fuel pumps is offered together with a range of brushless fuel pumps that suit our CFC Unit without any further modification.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cimg src=\"https:\/\/www.nukeperformance.com\/images\/150-05-204_textimage02.jpg\" alt=\"\" width=\"600\" height=\"400\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ci class=\"iconset iconset-info-circle\"\u003e\u003c\/i\u003e Utilizes internal high-pressure brushless fuel pumps, for any need between 200 - 2000 horsepower\u003c\/strong\u003e\u003cbr\u003eT\u003cspan\u003ehe CFC Units from Nuke Performance uses a billet fuel pump hanger and fits a single or dual brushless high-pressure fuel pump from Protec and Deatschwerks. As brushless fuel pumps use more connectors, but at the same time fewer amps, this CFC Unit is equipped with a 6-pin bulkhead electrical connector that lets you connect a single or dual brushless fuel pump within the surge tank. This solution is ready to deliver steady fuel flow for demands anywhere between 200-2500 horsepower without fuel starvation, even during demanding driving conditions, thanks to the internal surge tank.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003ci class=\"iconset iconset-check-box\"\u003e\u003c\/i\u003e Fits 1 or 2 \u003cstrong\u003eProtec Brushless Cobra Compact\u003c\/strong\u003e in-tank fuel pumps\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003e\u003ci class=\"iconset iconset-check-box\"\u003e\u003c\/i\u003e Fits 1 or 2 \u003cstrong\u003eDeatschwerks DW440 \/ DW810 Brushless\u003c\/strong\u003e fuel pumps\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003e\u003ci class=\"iconset iconset-check-box\"\u003e\u003c\/i\u003e Designed to use a single or dual \u003cstrong\u003eadditional venturi pickup\u003c\/strong\u003e line\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003e\u003ci class=\"iconset iconset-check-box\"\u003e\u003c\/i\u003e Safe \u003cstrong\u003efor all types of fuel\u003c\/strong\u003e, including alcoholic fuels such as E85\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe CFC Unit for brushless fuel pumps is developed for use with the Protec Brushless Cobra Compact and Deatschwerks DW440 Brushless fuel pumps. In combination with the Nuke Performance fuel pump mounting kits, it has never been this easy to set up a high-performance fuel system. Every part of the CFC Unit is guaranteed to work perfectly with alcoholic fuels like ethanol, even through long-term usage. It also fits common 39-mm fuel pumps, but as these fuel pumps use more amps it's recommended to use the other CFC Unit models available with the fail-proof 6-mm connectors.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/www.nukeperformance.com\/images\/150-05-204_textimage03.jpg\" alt=\"\" width=\"600\" height=\"400\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ci class=\"iconset iconset-info-circle\"\u003e\u003c\/i\u003e\u003cstrong\u003e How to mount fuel pumps within the Nuke Performance high-profile CFC Unit for brushless fuel pumps?\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eThe single fuel pump mounted in the fuel cell functions as a feeder fuel pump, ensuring that the high-pressure fuel pumps within the oversized 2.0-liter (0.53 gallons) surge tank always have enough fuel to maximize flow and minimize the risk of starvation, which could seriously harm your engine. For more information, view the product manual. The brushless fuel pump edition CFC Unit is delivered with everything you need to install the fuel pumps of your selection, but we recommend adding one of our fuel pump mounting kits for optimal functionality. All fuel pumps are securely mounted in all conditions thanks to the billet fuel pump brackets.\u003cbr\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cimg src=\"https:\/\/www.nukeperformance.com\/images\/150-08-000-m02.jpg\" alt=\"\" width=\"515\" height=\"302\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ci class=\"iconset iconset-info-circle\"\u003e\u003c\/i\u003e Which brands and what type of fuel cells can be used with the high-profile version of the CFC Unit from Nuke Performance?\u003cbr\u003e\u003c\/strong\u003e\u003cspan\u003eThe high-profile CFC Unit is developed out of the low-profile version, but with the addition of being able to, without any modifications, mount the CFC Unit into the popular Saver Cell fuel cells from ATL, and Fuel Safe fuel cells. These fuel cells have a smaller opening than other common fuel cells, demanding this new design.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.nukeperformance.com\/category.html\/fuel-cells\"\u003e\u003cspan\u003e\u003cimg src=\"https:\/\/www.nukeperformance.com\/images\/150-05-204_textimage06.jpg\" alt=\"\" width=\"1000\" height=\"70\"\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eOne benefit of this higher profile design is that it requires less minimum mounting depth, at 197-mm (7.75\") instead of the 219-mm from the previous slim-design version. This high-profile version offers the minimum mounting depth and fits smaller openings while boasting the same undisputable top-notch functionality and just a little bit more weight than the low-profile lightweight version.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/www.nukeperformance.com\/images\/150-05-204_textimage07.jpg\" alt=\"\" width=\"600\" height=\"400\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ci class=\"iconset iconset-info-circle\"\u003e\u003c\/i\u003e\u003cstrong\u003e Offered with a selection of fuel cells from ATL, Pyrotect, and Nuke Performance, all delivered with the preferred CFC Unit\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eChanging from a stock fuel tank to an aftermarket, FIA-approved fuel cell has never been easier. We offer the high- and low-profile CFC Unit in combination with fuel cells from ATL and Pyrotect. For a simple and affordable solution when not in need of homologation, check out the Alucell 40\/60-liter fuel cells from Nuke Performance.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003ci class=\"iconset iconset-check-box\"\u003e\u003c\/i\u003e Available with \u003cstrong\u003eFIA-homologated fuel cells\u003c\/strong\u003e from ATL and Pyrotect\u003cbr\u003e\u003ci class=\"iconset iconset-check-box\"\u003e\u003c\/i\u003e Fits the affordable AluCell fuel cells from Nuke Performance\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eSelect your preferred CFC Unit that fits according to your selected fuel pump setup. This version is designed with additional electrical connectors that manage all the wiring that is needed when using brushless fuel pumps from Protec, Deatschwerks, Fuelab, and others.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cimg src=\"https:\/\/www.nukeperformance.com\/images\/150-22-206_textimage01.jpg\" alt=\"\" width=\"600\" height=\"400\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ci class=\"iconset iconset-info-circle\"\u003e\u003c\/i\u003e NEW : The Fuel Cell Vent Kit AN-6 fits straight to the vent valve of the CFC Unit for easy installation\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eThe CFC Unit is equipped with a roll-over protected AN-8 (3\/4 UNF) to AN-6 Male vent fitting, and the easiest way to route the vent line into a safe and functional position is to accommodate a fuel cell vent kit from Nuke Performance. Available in several sizes, from AN-6 to AN-12, you can choose the kit that suits your needs the best. If you want to use a larger vent line than AN-6, you also need to swap the fitting on the vent valve.The vent kit is delivered with a 1m (3.3ft) nitrile fuel hose and a universal air filter that prevents debris to get into your fuel system.\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003eFuel Cell Vent Valve AN-6 Part \u003c\/strong\u003e\u003ca href=\"https:\/\/www.nukeperformance.com\/product.html\/fuel-cell-vent-kit\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003cstrong\u003eAN-8 (3\/4 UNF) to Male Adapters \u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cimg src=\"https:\/\/www.nukeperformance.com\/images\/150-05-204_textimage04.jpg\" alt=\"\" width=\"600\" height=\"400\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ci class=\"iconset iconset-info-circle\"\u003e\u003c\/i\u003e\u003cstrong\u003e Our wide variety of fittings and fitment possibilities suits your every need for fuel delivery within an aftermarket fuel system\u003c\/strong\u003e\u003cbr\u003eThe CFC Unit uses AN-10 ORB outlet and AN-8 ORB return inlet fittings. The use of the oversized, high flow AN-10 ORB outlet combines the internal fuel pumps into one single fuel line and minimizes the need for external equipment, hoses, and fittings. The included rollover protected vent fitting is of AN-6 (3\/4 UNF) and can be swapped for AN-6 to AN-10 when needed. Outlet and return AN-6, AN-8, AN-10, and AN-12 fittings are sold separately as accessories.\u003cbr\u003e\u003cstrong\u003e\u003ci class=\"iconset iconset-info-circle\"\u003e\u003c\/i\u003e Outlet fittings :\u003c\/strong\u003e\u003cbr\u003eAN-10 ORB to AN-6 Male Part # : 700-04-108\u003cbr\u003eAN-10 ORB to AN-8 Male Part # : 700-04-109\u003cbr\u003eAN-10 ORB to AN-10 Male Part # : 700-04-110\u003ca href=\"https:\/\/www.nukeperformance.com\/product.html\/10an-orb\"\u003e\u003c\/a\u003e\u003cbr\u003eAN-10 ORB to AN-12 Male Part # : 700-04-111\u003cbr\u003e\u003cstrong\u003e\u003ci class=\"iconset iconset-info-circle\"\u003e\u003c\/i\u003e Return fittings :\u003c\/strong\u003e\u003cbr\u003eAN-8 ORB to AN-6 Male Part # : 700-04-104\u003cbr\u003eAN-8 ORB to AN-8 Male Part # : 700-04-105\u003cbr\u003eAN-8 ORB to AN-10 Male Part # : 700-04-106\u003cbr\u003eAN-8 ORB to AN-12 Male Part # : 700-04-107\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/www.nukeperformance.com\/images\/150-05-201_textimage06.jpg\" alt=\"\" width=\"600\" height=\"400\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ci class=\"iconset iconset-info-circle\"\u003e\u003c\/i\u003e \u003cstrong\u003eHow does the Nuke Performance Competition Fuel Cell Unit work?\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eThe CFC Unit works as a fuel pump hanger with an integrated surge tank for motorsports applications where safety and functionality are of uttermost importance. It is designed to mount directly to an aftermarket fuel cell with a standardized 24-bolt pattern. For more information about the functionality of the CFC Unit, view our Youtube video explaining its functions or visit our FAQ guidé that tells you more about the CFC Unit.\u003c\/span\u003e\u003cbr\u003e\u003ci class=\"iconset iconset-download\"\u003e\u003c\/i\u003e \u003ca href=\"https:\/\/www.nukeperformance.com\/dokument\/product_manual_PM0150-003.pdf\"\u003e\u003cstrong\u003eProduct Manual :\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDownload our detailed product manual!\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/www.nukeperformance.com\/images\/150-05-204_textimage09.jpg\" alt=\"\" width=\"600\" height=\"400\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ci class=\"iconset iconset-info-circle\"\u003e\u003c\/i\u003e\u003cstrong\u003e How to connect fuel pumps to the electrical connectors and fuel lines?\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eThe Competition Fuel Cell Unit (CFC Unit) for brushless fuel pumps, with an integrated fuel surge tank, utilizes a bulkhead 6-pin connector to manage the needed wiring points when using brushless fuel pumps. The CFC Unit arrives with the bulkhead connector, pins, and male\/female connectors necessary to mount a single or dual brushless fuel pump mounted within the surge tank. Each brushless fuel pump uses 3 pins for its external controller unit. With the use of fewer amps, the bulkhead connector makes a perfect match for a simple and service-friendly solution.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003ci class=\"iconset iconset-check-box\"\u003e\u003c\/i\u003e \u003cstrong\u003eBulkhead 6-pin connector\u003c\/strong\u003e for the high-pressure fuel pumps\u003cbr\u003e\u003ci class=\"iconset iconset-check-box\"\u003e\u003c\/i\u003e 3 x 6 mm connectors for the additional lift pump\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe additional 6-mm electrical connectors are meant to be used for the lift pump, and with the three connectors, you have many options to choose from. You can mount a brushless lift pump, a low-pressure lift pump, or even a dual low-pressure setup if you want to mount the fuel pumps in each corner of the fuel cell. The fuel line connects to the included barb fittings, but we recommend adding one of the fuel pump mounting kits for your selected fuel pumps to get all the benefits of easy maintenance, fail-proof functionality, and long-term durability even when running alcoholic fuels such as ethanol.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ci class=\"iconset iconset-info-circle\"\u003e\u003c\/i\u003e Additional venturi pickup line ensures the surge tank internal fuel level even when using the smallest pickup pump\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eBoth the Protec Brushless Cobra Compact and Detschwerks DW440 Brushless in-tank fuel pumps let you connect an additional venturi pickup kit. The venturi kit is not meant to be used alone, without the use of a pickup pump. Its purpose is to help to ensure the fuel level within the internal surge tank while at the same time accommodating a smaller and lower flow-lift fuel pump mounted within the fuel cell. The CFC Unit for brushless fuel pumps has room and functionality for a dual venturi kit installed alongside a single lift pump, all at the same time.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/www.nukeperformance.com\/images\/150-05-201_textimage12.jpg\" alt=\"\" width=\"600\" height=\"400\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ci class=\"iconset iconset-info-circle\"\u003e\u003c\/i\u003e\u003cstrong\u003e Low profile fuel filler cap or remote fill neck for 50mm fuel fill hose?\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eThe high-profile CFC Unit is delivered with a low-profile filler cap with integrated roll-over protection. But for those who prefer a remote fill, we offer a remote filler neck for a 50-52 mm fuel fill hose. It fits straight into the CFC Unit and uses integrated roll-over protection mounted on the underside of the CFC Unit. The remote filler neck is available as an accessory.\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003eRemote filler neck for 50mm fuel hose Part # :\u003c\/strong\u003e 150-05-202\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/www.nukeperformance.com\/images\/150-05-201_textimage13.jpg\" alt=\"\" width=\"600\" height=\"400\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003ci class=\"iconset iconset-info-circle\"\u003e\u003c\/i\u003e\u003cstrong\u003e Choose the right Fuel Level Sender Unit for your aftermarket fuel cell\u003c\/strong\u003e\u003cbr\u003eFor most applications, an accurate fuel level sender is required to get an optimal experience. The Nuke Performance CFC Unit fits the most common fuel level senders that utilize the 5-bolt SAE pattern. The CFC Unit is delivered with a low profile and lightweight, block-off plate that easily can be swapped for a fuel level sender of choice. You can get your CFC Unit delivered with an FLS, make sure to select the right length when placing an order. For easy selection, measure the depth of your fuel cell and subtract approx 20mm (0.78\") and select the fuel level sender that comes closest to your measurement.\u003cbr\u003e\u003ci class=\"iconset iconset-info-circle-btm\"\u003e\u003c\/i\u003e\u003cstrong\u003e 0-90 Ohms FLS Unit \u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cimg src=\"https:\/\/www.nukeperformance.com\/images\/150-05-201_textimage14.jpg\" alt=\"\" width=\"600\" height=\"400\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003ci class=\"iconset iconset-info-circle\"\u003e\u003c\/i\u003e \u003cstrong\u003eHow to fit any of the CFC Units from Nuke Performance to your own custom fuel cell\u003c\/strong\u003e\u003cbr\u003eThe CFC Unit from Nuke Performance is made to fit the standard 24-bolt pattern 6x10\". We offer an aluminum flange that makes it possible to bolt the CFC Unit to a custom-manufactured fuel cell that uses this standard pattern. You can either weld it to your aluminum cell or copy the pattern to your top sheet and bolt the CFC Unit to it putting the top sheet in between the flange and the CFC Unit. The CFC Unit arrives with a Viton gasket (safe for all types of fuels), which fits perfectly for custom fuel cell applications.\u003cbr\u003e\u003cstrong\u003eAluminum weld flange 24 bolt pattern Part # :\u003c\/strong\u003e 150-05-300\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cimg src=\"https:\/\/www.nukeperformance.com\/images\/150-05-201_textimage15.jpg\" alt=\"\" width=\"600\" height=\"400\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003ci class=\"iconset iconset-info-circle\"\u003e\u003c\/i\u003e\u003cstrong\u003e Complete your high flow fuel system with Nuke Performance Full Flow series fuel lines, hose ends, and fittings\u003c\/strong\u003e\u003cbr\u003eNuke Performance offers a wide variation of both PTFE and nitrile fuel line systems for your every fueling need. The lightweight fuel cell fill plate replacements from Nuke Performance are a perfect match to the Nuke Performance Full Flow-series fuel lines. Available in AN-4 to AN-12 and in a wide variation of available fittings and accessories. And with the handy selection of fuel line tools, it has never been as easy to assembly your fuel system.\u003cbr\u003e\u003cstrong\u003ePTFE Full Flow series AN-6 to AN-12 \u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eAN Full Flow series AN-4 to AN-12\u003c\/strong\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cimg src=\"https:\/\/www.nukeperformance.com\/images\/150-06-08_textimage05.jpg\" alt=\"\" width=\"600\" height=\"400\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ci class=\"iconset iconset-info-circle\"\u003e\u003c\/i\u003e\u003cstrong\u003e Made in Sweden with high demands from worldwide motorsports\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eCo-developed with worldwide motorsports teams, it has become a common sight in motorsports such as time-attack, drifting, and GT racing. Saving weight is often equally important as chasing horsepower, and for several of our customers, they have been able to perform weight savings of more than 10kg by upgrading to our compact and lightweight solution. The Nuke Performance CFC Unit for brushless fuel pumps - Competition Fuel Cell Unit, with integrated fuel surge tank, is a perfect fit for aftermarket fuel cells and is designed, developed, and manufactured in Sweden with the highest possible quality, with the same hallmark as the other parts in the lightweight Nuke Performance motorsports range.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eThere is no substitute for the quality of Nuke Performance.\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003cp\u003e\u003ci class=\"iconset iconset-info-circle\"\u003e\u003c\/i\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eNuke Performance CFC Unit for brushless fuel pumps specifications\u003c\/strong\u003e\u003cspan\u003e\u003cbr\u003eFor more information about CFC Unit specifications, \u003ca href=\"https:\/\/www.nukeperformance.com\/dokument\/product_manual_PM0150-003.pdf\"\u003eview the product manual\u003c\/a\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable border=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e High profile CFC Unit Part # \u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e150-05-204\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e Minimum mounting depth\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e197mm (7.75”)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e Mounting bolt pattern\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6x10\" 24-bolt pattern\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e High-pressure fuel pump connector\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6-pin bulkhead connector\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003e - Connector points\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ex 6 (max 30 ampere \/ each *)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003e Pickup fuel pump connector\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6 mm bolt connector\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003e - Connector points\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ex 3 (max 125 ampere \/ each *)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e Length\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e295mm (13.74”)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e Width\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e194mm (9.88\")\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003e Weight\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2254g (4.96lb)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003e Fits number of lift fuel pumps\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 x brushless fuel pump (2 x brushed)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003e Fits number of high-pressure pumps\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 x brushless fuel pumps\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003e Fuel compatibility\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGasoline, Methanol, Ethanol, E85\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e Fits additional venturi lift kit\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYES - fits 1-2 additional venturi kit\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e Internal surge tank volume\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eApproximately 2.0 liter (0.53 gallons)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e Outlet port, thread\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAN-10 ORB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e Return port, thread\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAN-8 ORB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e Vent valve, thread\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAN-8 (3\/4 UNF)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e Vent valve fitting included\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAN-8 (3\/4 UNF) to AN-6 Male\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e For motorsports use\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYES\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e* for reference only\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003ci class=\"iconset iconset-info-circle\"\u003e\u003c\/i\u003e\u003cstrong\u003e High-profile CFC Unit for brushless fuel pumps includes:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003e1 x Nuke Performance CFC Unit - high profile version for brushless fuel pumps\u003cbr\u003e1 x Delphi 6-pin bulkhead connector with Viton O-ring seal\u003cbr\u003e2 x Female electrical connectors with 6 connection pins each\u003cbr\u003e2 x 1\/4\" BSPP to Male barb 8mm hose fittings\u003cbr\u003e1 x 1\/4\" BSPP plug, when using only one high-pressure fuel pump\u003cbr\u003e2 x 39mm inserts for high-pressure fuel pump bracket\u003cbr\u003e2 x 42mm inserts for high-pressure fuel pump bracket\u003cbr\u003e1 x Viton gasket for 24 bolt pattern fuel cells (safe for alcoholic fuels)\u003cbr\u003e1 x Low profile filler cap (remote fill neck available as accessory)\u003cbr\u003e1 x Dual billet fuel pump bracket and adjustable pickup pump mount\u003cbr\u003e1 x AN-8 (3\/4 UNF) to AN-6 Male vent safety valve\u003cbr\u003e1 x FLS spacer, used for fuel level senders with a not symmetrical bolt pattern\u003cbr\u003e24 x 1\/4-28 UNF x 1 bolts with nylon washers\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003ci class=\"iconset iconset-search-btm\"\u003e\u003c\/i\u003e \u003ca href=\"https:\/\/www.nukeperformance.com\/dokument\/product_manual_PM0150-003.pdf\"\u003e\u003cstrong\u003eDownload User Manual\u003c\/strong\u003e\u003c\/a\u003e (.pdf)\u003c\/span\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ci class=\"iconset iconset-warning-entypo\"\u003e\u003c\/i\u003e No modification is needed before installation\u003cbr\u003e\u003c\/strong\u003e\u003cspan\u003eThe new high-profile version of the Nuke Performance CFC Unit requires no modifications to an ATL or Fuel Safe fuel cell before installation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ci class=\"iconset iconset-warning-entypo\"\u003e\u003c\/i\u003e No fuel pumps are included with the CFC Units\u003cbr\u003e\u003c\/strong\u003e\u003cspan\u003eThe CFC Unit is delivered without fuel pumps, if needed you select the preferred fuel pump in our selection menu.\u003c\/span\u003e\u003c\/p\u003e","brand":"Nuke Performance","offers":[{"title":"Default Title","offer_id":51485027074390,"sku":"150-05-204","price":740.1,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6119\/2790\/files\/2481-82-150-05-204_01.jpg?v=1759599796","url":"https:\/\/driftmafia.life\/products\/nuke-performance-cfc-unit-for-brushless-fuel-pumps-competition-fuel-cell-unit-with-integrated-fuel-surge-tank","provider":"DriftMafia","version":"1.0","type":"link"}